LX3VM-3624MT
Classification:
- 2
- 1
-
General specifications
LX3V series host
LX3VP series host
LX3VE/LX3VM series host
Execution method
Cycle scan/interrupt mode
Programming method
Instruction list/ladder diagram
Command type
Basic instruction: 27/application instruction: 136+2
Application instruction 140
Execution time
Basic instruction: 0.06 microseconds / application instruction: 1~10 microseconds
Program capacity
16K
64K
32K
Download and monitor
Programming cable (serial type)/Micro USB
High-speed pulse output
Transistor type: 2 channels (extended 4 channels)/relay type: none (extended 2 channels)
High-speed counter interrupt
6 way
Timed interrupt
3 way
Power-down save function
Can be adjusted by software
Storage medium
FLASH
Digital filtering
Perform digital filtering on all inputs
Serial communication
COM1: RS422 or RS485
COM2: RS485
Ambient temperature
Working temperature: 0~55℃/Storage temperature: 0~70℃
Environmental humidity
35~85% RH (no condensation)
Impact resistant
Comply with JIS C 0040 standard
Noise resistance
Comply with IEC61000-4-4 and GB/T 17626.4: noise voltage amplitude 1KVP-P, 10us pulse width, 0.3S period, edge 5ns; continuous action for 1 minute.
Output specifications
Project
Relay output
Transistor output
Output type
--
NPN
Input loop
DC 24V
DC 24V
Output circuit
<AC 250V or < DC 30V
DC 5~30V
COM port current
--
<0.1mA(DC 30V)
Circuit insulation
Mechanical insulation
Photoelectric coupling insulation
Open circuit leakage current
--
0.1mA/DC 30V
Minimum load
DC 5V 2mA
--
Maximum output current
Resistive load
2A/output terminal, 8A/COM terminal
0.5A/output terminal, 0.8A/COM terminal, 0.3A/high-speed output terminal
Inductive load
80VA
12W/DC 24V (High-speed output terminal: 7.2W/terminal)
Light load
100W
0.9W/DC 24V
Response time
ON response
<10ms
<0.2ms
(High-speed output terminal: <5us)OFF response AC power specifications
Project
Hosts below 26 o'clock (including 26 o'clock)
Hosts above 26 points
Voltage range
AC 85~265V 50~60Hz
Allow instantaneous stop time
The host can continue to work after 10ms momentary power failure
Impulse current
<15A 5ms/AC 100V;<30A 5ms/AC 200V
Power fuse
250V 3.15A
250V 3.15A
Power consumption
<35w
<60w
Output power
DC 24V 700mA
DC 24V 700mA
DC power supply specifications
Project
LX3V/LX3VP/LX3VE/LX3VM host
Voltage range
DC 24V±10%
Allow instantaneous stop time
The host can continue to work after 10ms momentary power failure
Power fuse
250V 3.15A
Impulse current
<15A 1ms/DC 24V
Power consumption
<30w(Excluding the external power supply part of the expansion module)
-